Surplus panelboards are easier to review when the record shows both the complete assembly and what is present as separate devices, fittings, or shipping splits. From existing documentation and safe exterior photographs, you can describe the board’s ratings, arrangement, condition, completeness, and access. Louisiana Switchgear Buyer assesses the equipment before making an offer; acceptance is not guaranteed, and no seller testing is required.

Start with an assembly-level inventory

Identify each panelboard or related assembly as a separate item, then give its location within your facility records, if useful, and the number of boards or sections involved. Note whether the equipment is a complete board, a partial assembly, or a collection of components. Record any section or frame dimensions already available on drawings or shipping documents. This overview helps distinguish one integrated unit from multiple items and makes it easier to compare the listed equipment with photographs. Do not remove covers or parts to improve the inventory; describe only what records show or what is safely visible from outside.

Describe the main and feeder arrangement

Use existing schedules, drawings, or labels to report the main device arrangement and the number or type of feeder positions, where documented. Say whether a main breaker, main lugs, or another configuration is indicated; do not infer a configuration from appearance alone. List known feeder devices separately from empty spaces, and flag any positions whose contents are uncertain. If the board has been divided for shipping, note the number of splits and any labels that identify how sections relate. These details help a buyer understand the panelboard’s configuration and identify which loose devices or accessories belong with which assembly.

Transcribe ratings from records and markings

Provide the voltage class, phase, frequency, and continuous-current or bus rating when shown on a nameplate, schedule, or other existing record. Include interrupting or withstand markings only when legible and clearly associated with the equipment. Report enclosure style or rating as marked; avoid assigning a rating based on the installation environment or a visual guess. If documents and nameplate information differ, note the discrepancy rather than choosing one value. A clear transcription supports an initial review of application and configuration, but it does not establish current operating condition or replace the buyer’s assessment.

Make loose parts countable

Prepare a list from existing inventory records of separate breakers, filler plates, trim, doors, hinges, handles, lugs, barriers, and other fittings included with the panelboard. For devices, record count and any visible catalog or type markings available without handling energized equipment. Distinguish parts attached to the assembly from items stored separately, and identify containers or shipping splits by their existing labels. If a component’s fit or association is unknown, say so. A countable, itemized list helps the buyer review completeness and compatibility without assuming that every device or accessory is suitable for every position.

Photograph the outside safely

Useful photographs include the full assembly, visible nameplates, representative device faces, doors, exterior compartments, fittings, and loose parts arranged for identification. Include a safe scale reference, such as a nearby fixed object, only where it can be captured without approaching a hazard or obstructing access. Keep labels readable when possible, and connect detail images to the relevant board or shipping split in your inventory. Take photographs only from a safe location and follow your facility’s access controls. Do not open energized compartments, remove covers, operate devices, or handle electrical equipment to obtain a better image.

Report condition and completeness carefully

Describe what is known from records and safe visual observation: for example, whether doors or fittings appear present, whether listed devices are accounted for, and whether documents note missing items or prior removal. Separate confirmed facts from estimates, and identify unknowns plainly. Do not call a panelboard operational, tested, or complete unless supported by reliable records; seller testing is not required for a buyer review. Disclose known damage or storage-related concerns when documented. This measured description helps the buyer assess the assembly and loose-parts package while avoiding assumptions about internal condition, device performance, or compatibility.

Include access and removal information

Provide practical site details that help plan a review and, if a transaction is agreed, removal: where the equipment is located, its known dimensions or weight, available route information, and any access restrictions or lifting constraints already documented. Do not disconnect, rig, lift, or load the equipment yourself. Qualified professionals must handle electrical isolation and all rigging or lifting. Louisiana Switchgear Buyer handles and pays for qualified disconnects, crane and rigging, loading, freight, and hauling on agreed transactions. After reviewing the information and equipment, the buyer may make a cash offer; payment is upfront when transaction terms are agreed.

Real electrical switchgear photograph for Panelboards: loose-parts

Buyer notes

Send the facts that move the review forward.

Include the nameplate, lineup or device photos, approximate quantity, visible condition and where the equipment is located. We buy equipment; we do not sell replacement gear or represent a test result that has not been provided.

Text nameplate photos

Start with the nameplate

Request a quote

Tell us what you have. We buy switchgear from decommissioned data centers, shut-down power plants and other facilities. Crane, rigging, disconnects, loading, freight and hauling are on us. You do nothing but get paid.

Up to three images, 10 MB combined. You can also text nameplate photos to (614) 715-3047.

We handle the heavy lifting

We buy it. We move it. You get paid.

We buy switchgear out of decommissioned data centers and shut-down power plants. Crane, rigging, disconnects, loading, freight and hauling are on us. The seller does nothing but get paid.

Request a Quote
Request a Quote