Document surplus Switchboards through a rating review

Cash offers for used and surplus electrical equipment. No testing required. We handle crane, rigging, disconnects, loading, freight and hauling—you do nothing but get paid.

Payments Upfront
No Testing
We Cover All Freight
All Voltage Classes Bought

Before requesting an offer for surplus switchboards, record the assembly’s visible ratings, section count, main and feeder arrangement, and what remains with it. A switchboard is a coordinated low-voltage distribution assembly, not simply a collection of breakers: its bus, protective devices, metering, enclosure, and section layout affect how a buyer can assess the equipment. Clear records help distinguish what is present from what is unknown.

Start with the assembly and its sections

Count the connected sections and note whether the switchboard is assembled, divided into shipping splits, or partly dismantled. Record approximate section or frame dimensions where they can be obtained safely, and identify the main section, feeder sections, metering area, and any apparent blanks or open positions. Distinguish equipment mounted in the lineup from loose components stored nearby. A written section-by-section inventory is more useful than one total device count because it preserves the assembly’s layout and shows which parts belong together. Do not remove covers or enter electrical compartments to gather these details.

Capture the ratings as marked

Transcribe the voltage class, phase, frequency, and continuous current or bus rating from visible nameplates and markings. Include interrupting or withstand ratings only when they are legible and clearly associated with the equipment; do not infer them from a breaker model or from a similar-looking lineup. Note the nameplate location and photograph the marking in context as well as close up. If a field is unreadable, record it as unreadable or unknown rather than estimating. Ratings describe important selection characteristics, but they do not establish present operating condition, completeness, or suitability for a future installation.

Describe mains, feeders, and bus

Summarize the apparent main-device arrangement and the number and types of feeder positions or devices. Record visible device labels, frame sizes, and accessories when identifiable, while separating confirmed markings from visual estimates. Note bus or conductor details only when shown on accessible nameplates or documentation; do not expose conductors to inspect them. Include metering equipment, control components, and apparent spare sections in the inventory. Switchboards with the same overall rating can differ substantially in feeder layout and installed devices, so a concise arrangement description helps an assessor understand the specific configuration rather than treating it as a generic assembly.

Record enclosure and completeness

Describe the enclosure style and visible state of doors, handles, barriers, fittings, and section-to-section connections. List missing or loose parts separately, including devices, trim, hardware, and accessories, and indicate whether their relationship to the lineup is known. Note visible damage, corrosion, contamination, or alterations without trying to diagnose their electrical significance. Include manuals, drawings, or component schedules if available. Avoid describing the switchboard as operational, tested, or ready for reuse unless reliable records establish that status. A precise account of what is present—and what is absent—supports a more informed assessment and avoids confusion later.

Make photographs useful and safe

Photograph the full assembly from a safe position, then take clear views of each section, visible nameplates, representative device faces, doors, compartments, fittings, and loose parts. Add a safe scale reference, such as a person standing clear or a measurement taken without contacting equipment. Keep images wide enough to show which section a close-up belongs to, and use captions or filenames to connect photographs with your inventory. Never open energized compartments, remove barriers, or approach exposed electrical parts for a better image. If safe access or isolation is uncertain, leave photography and assessment to qualified professionals.

Arrange assessment before a sale decision

Send the inventory, photographs, and available records for review so the switchboard can be assessed before an offer is made. Share known storage conditions, whether the assembly is intact or split, and any uncertainty about ratings or missing components. No seller testing is required; do not energize equipment or arrange informal electrical checks to fill gaps. Assessment does not guarantee acceptance, and an offer depends on the equipment presented and its documented details. If an offer is agreed, confirm in writing what equipment and loose parts are included, the sale terms, and the planned handover arrangements before removal is scheduled.

Plan recovery and payment around the agreed scope

For an agreed purchase, Louisiana Switchgear Buyer handles and pays for qualified disconnection, crane and rigging work, loading, freight, and hauling. The seller should identify site access constraints, the equipment’s location, and any known restrictions that may affect the recovery plan, without undertaking electrical or lifting work. Leave isolation, disconnection, and removal to qualified professionals. Payment is made upfront on agreed transactions; confirm the amount and payment arrangements before the work proceeds. Keep the agreed inventory available during handover so the recovered sections and included devices can be matched to the sale scope.

Real electrical switchgear photograph for Switchboards: rating

Buyer notes

Send the facts that move the review forward.

Include the nameplate, lineup or device photos, approximate quantity, visible condition and where the equipment is located. We buy equipment; we do not sell replacement gear or represent a test result that has not been provided.

Text nameplate photos

Start with the nameplate

Request a quote

Tell us what you have. We buy switchgear from decommissioned data centers, shut-down power plants and other facilities. Crane, rigging, disconnects, loading, freight and hauling are on us. You do nothing but get paid.

Up to three images, 10 MB combined. You can also text nameplate photos to (614) 715-3047.

We handle the heavy lifting

We buy it. We move it. You get paid.

We buy switchgear out of decommissioned data centers and shut-down power plants. Crane, rigging, disconnects, loading, freight and hauling are on us. The seller does nothing but get paid.

Request a Quote