Louisiana • We buy electrical equipment
(614) 715-3047   |   saleselectricalbuyers@gmail.com

Louisiana | We buy equipment

Document retired-generation-facility electrical equipment with attention to shipping splits

Cash offers for used and surplus electrical equipment. No testing required. We handle crane, rigging, disconnects, loading, freight and hauling—you do nothing but get paid.

Payments Upfront
No Testing
We Cover All Freight
All Voltage Classes Bought

A power plant teardown can leave electrical equipment arranged as complete lineups, separated sections, or mixed lots of devices and accessories. Shipping splits affect what can be evaluated and moved together, so document the physical groups rather than assuming the former installation defines a saleable assembly. Louisiana Switchgear Buyer reviews used, surplus and decommissioned equipment, including medium-voltage switchgear, station-service gear, breakers, MCCs, auxiliary panels and control equipment.

Map the lot as it sits

Start with a simple lot map showing each lineup, cabinet, loose device and accessory group. Mark which pieces appear connected or mounted together and which are already separated; do not dismantle equipment to make the map. A shipping split may follow a row of switchgear sections, divide station-service equipment from auxiliary panels, or leave breakers and control items in separate storage. Distinguishing these conditions helps a buyer assess the offered scope without treating nearby equipment as part of the same lot. Note any areas that are inaccessible or not included.

Separate complete assemblies from components

For each proposed group, state whether it appears to be a complete assembly, a partial lineup, or individual components. A complete-looking switchgear lineup may include several sections, while a separated breaker, relay, control panel or bus component may be offered independently. Record what is physically present, not what you expect the original installation to have included. Identify missing doors, covers, devices or accessories only when their absence is visible or confirmed. Do not remove covers or open energized compartments to check. A qualified professional must handle electrical isolation and any required access.

Record visible identity and ratings

Photograph nameplates and other legible markings on accessible equipment, then transcribe identifiers and ratings carefully. Useful details can include manufacturer, catalog or model number, serial number, voltage, current, interrupting rating and section designation when marked. Medium-voltage gear and station-service equipment can look similar while carrying different ratings or configurations, so avoid identifying a unit by appearance alone. If a plate is obscured, damaged or unreadable, record that as unknown rather than guessing. Keep each image tied to a specific lineup section, breaker or panel in the lot map.

Build a device and accessory list

List breakers, relays, meters, control devices and loose accessories separately from the assemblies they may have served. Include the quantity, visible markings, apparent location and whether each item is mounted, stored nearby or of uncertain association. This is particularly useful when teardown and shipping splits have separated breakers from switchgear sections or control equipment from auxiliary panels. Do not assume a loose device fits a particular cubicle just because it was found nearby. A buyer can assess the disclosed grouping, while compatibility and completeness remain subject to review of the available details.

Capture dimensions and shipping groups

Provide approximate overall dimensions for each shipping group when they can be obtained safely, and distinguish those measurements from dimensions of individual sections. Note whether equipment is staged as one lineup, split into sections, palletized, or otherwise grouped, without attempting to shift or lift it. Describe visible access constraints such as a narrow route, overhead obstruction or limited loading area, and identify which group each constraint affects. These details help assess handling and freight requirements. Louisiana Switchgear Buyer handles and pays for qualified disconnects, lifting, rigging, loading, freight and hauling on agreed transactions.

Include drawings and access notes

Share a one-line diagram or section schedule when available, but treat it as supporting documentation rather than proof that every listed item remains onsite. Compare the drawing labels with visible section identifiers and note mismatches or uncertain correspondences. Add access notes describing where each group is located and whether inspection or removal requires coordination with the facility. Do not perform electrical work or prepare equipment for shipment yourself; qualified professionals must manage isolation, disconnects and rigging. Include ownership or authorization status so the buyer can understand whether you are entitled to offer the equipment.

Make unknowns explicit before review

A concise record can show what is documented, what is visibly present and what remains unknown: missing drawings, unreadable nameplates, uncertain accessory matches, incomplete assemblies or dimensions not yet available. Send the device list, photos, lot map, access notes and any available schedules together so the proposed shipping splits are clear. Assessment precedes an offer, and acceptance is not guaranteed. No seller testing is required. For an agreed purchase, payment is made upfront, and removal and transportation are handled by the buyer rather than assigned to your staff.

Real electrical switchgear photograph for Power plant teardown equipment review: shipping splits

Buyer notes

Send the facts that move the review forward.

Include the nameplate, lineup or device photos, approximate quantity, visible condition and where the equipment is located. We buy equipment; we do not sell replacement gear or represent a test result that has not been provided.

Text nameplate photos

Start with the nameplate

Request a quote

Tell us what you have. We buy switchgear from decommissioned data centers, shut-down power plants and other facilities. Crane, rigging, disconnects, loading, freight and hauling are on us. You do nothing but get paid.

Up to three images, 10 MB combined. You can also text nameplate photos to (614) 715-3047.

We handle the heavy lifting

We buy it. We move it. You get paid.

We buy switchgear out of decommissioned data centers and shut-down power plants. Crane, rigging, disconnects, loading, freight and hauling are on us. The seller does nothing but get paid.

Request a Quote
Request a Quote